This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-14. 2 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
24.75 in · Fit role: Traffic projection. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 24-in appliance depth + standard 3/4-in furniture panel
Confidence label: high.
Primary evidence
Thermador measurement source — T36IR905SP-105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador pages visually verify a 24-in appliance body and the manufacturer planning branch based on a standard/typical 3/4-in furniture panel, yielding 24 3/4 in without a handle.
Exact-model Thermador pages visually verify a 24-in appliance body and the manufacturer planning branch based on a standard/typical 3/4-in furniture panel, yielding 24 3/4 in without a handle. Calculation or inference: 24-in appliance depth + standard 3/4-in furniture panel.
Other evidence found
35.75 in — superseded
Document 105166495.pdf; page 1. Model scope: not separately recorded. Raw value: H x W x D) (in.)
83 3/4"* x 35 3/4". The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Custom handle projection varies; standardized scenario. Calculation or inference: 24.75-in installed depth + standard 1-in handle.
Other evidence found
35.75 in — superseded
Document 105166495.pdf; page 1. Model scope: not separately recorded. Raw value: H x W x D) (in.)
83 3/4"* x 35 3/4". The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
62.6875 in · Fit role: Operating clearance. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 24 + 38 11/16 = 62 11/16 in
Confidence label: high.
Primary evidence
Thermador measurement source — 105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-10-14
The drawing measures the door at 90° from the cabinet (or case) front: 38 11/16" ; top view: 24" (610 mm) from the back wall to the cabinet front. Stored from the back, like every other model: 24 + 38 11/16 = 62 11/16 in (owner decision 2026-10-14). The printed 38 11/16" is the front-of-cabinet figure.
The drawing measures the door at 90° from the cabinet (or case) front: 38 11/16" ; top view: 24" (610 mm) from the back wall to the cabinet front. Stored from the back, like every other model: 24 + 38 11/16 = 62 11/16 in (owner decision 2026-10-14). The printed 38 11/16" is the front-of-cabinet figure. Calculation or inference: 24 + 38 11/16 = 62 11/16 in.
Other evidence found
38.6875 in — superseded
The same document as the value used above; page 2. Model scope: not separately recorded. Raw value: Exact-model Thermador Freedom column sheet.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-05
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-05
Exact product sheet required cutout is 25 in deep; replaces the appliance-depth value 24 in.
Exact product sheet required cutout is 25 in deep; replaces the appliance-depth value 24 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Thermador measurement source — T36IR905SP-105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.125 in exactly for side_ventilation_clearance_in while preserving the documented installation branch.
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.125 in exactly for side_ventilation_clearance_in while preserving the documented installation branch. Calculation or inference: (min_cutout_width_in - case_width_in) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Thermador measurement source — T36IR905SP-105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.125 in exactly for side_ventilation_clearance_in while preserving the documented installation branch.
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.125 in exactly for side_ventilation_clearance_in while preserving the documented installation branch. Calculation or inference: (min_cutout_width_in - case_width_in) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Thermador measurement source — T36IR905SP-105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-11
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.25 in exactly for top_clearance_in while preserving the documented installation branch.
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 0.25 in exactly for top_clearance_in while preserving the documented installation branch. Calculation or inference: min_cutout_height_in - height_hinge_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Thermador measurement source — T36IR905SP-105166495.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-11
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 1 in exactly for rear_clearance_in while preserving the documented installation branch.
Exact-model Thermador planning page visually verified. Printed installation and appliance operands reproduce 1 in exactly for rear_clearance_in while preserving the documented installation branch. Calculation or inference: min_cutout_depth_in - depth_case_only_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 105166495.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Selected: 24.75 in. Earlier retained values: 35.75 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Thermador pages visually verify a 24-in appliance body and the manufacturer planning branch based on a standard/typical 3/4-in furniture panel, yielding 24 3/4 in without a handle. Calculation or inference: 24-in appliance depth + standard 3/4-in furniture panel.
Selected: 62.6875 in. Earlier retained values: 38.6875 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
The drawing measures the door at 90° from the cabinet (or case) front: 38 11/16" ; top view: 24" (610 mm) from the back wall to the cabinet front. Stored from the back, like every other model: 24 + 38 11/16 = 62 11/16 in (owner decision 2026-10-14). The printed 38 11/16" is the front-of-cabinet figure. Calculation or inference: 24 + 38 11/16 = 62 11/16 in.
Model numbers covered: T36IR905SP. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
10 displayed measurements supported: Overall width; Cabinet height; Height with hinge / controlling height; Depth without door; Depth with handle; Depth with doors open at 90°; Minimum cutout width; Minimum cutout height; Minimum cutout depth; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-14. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.