This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-09-05. 3 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row identifies the model relationship and supporting evidence.
Measurements and supporting evidence
Measurement
Value used
Evidence status
Primary source
Location
Details
Overall width
35.25 in
✓ Secondary source only
T36BT120NS s1.img-b.com
Page 2
Value used by ExactFit
35.25 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
T36BT120NS s1.img-b.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Cabinet height. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Height with hinge / controlling height. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Depth without door. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Depth with door, without handles. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Depth with handle. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
https://files.bbystatic.com/DcvHM3BU9fgM7NDp6DwaMw%3D%3D/specification%2Bsheet; location not retained. Model scope: not separately recorded. Raw value: l Height (Inches) 83 9/16 16" Min. - 85 1/2" Max. Overall Depth Without Panel or Handles (Inches) 24" Overall Depth With Panel (Inches) 24 3/4" Overall. The final reviewed registry supersedes this earlier audit value. Conflict-free left/right or handle-style sibling propagation.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Depth with doors open at 90°. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador T36BT120NS Product Specification assets.skulytics.io · Product Specification Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-04
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
Other evidence found
1 in — superseded
https://files.bbystatic.com/DcvHM3BU9fgM7NDp6DwaMw%3D%3D/specification%2Bsheet; location not retained. Model scope: not separately recorded. Raw value: page 4 of 5 6 / 24 proud install top view clearance proud install cutout dimensions measurements in inches (mm) 351/2-36 (900-914) 1/8-3/8 (3-10) ≥ 24 (≥ 610) 33/4 (95) 105/8 (270) 115° 115° 21 (533) 90° 90° (a) c 84 (2134) ≤ 71/4 (≤ 185) (b) ≥ 4 (≥ 100) (c) ≥ 4 (≥ 100) (c) c2 d ≥ 4 (≥ 100) (c) c1 ≥ 24 (≥ 610) 351/2-36 (900-914) c1: c2: d: c: b: a: furniture return frameless cabinet framed cabinet filler area for water and electric line routing socket measurements in inches (mm) t36bt120ns 36-inch built-in french door refrigerator, 2 drawer, pre-assembled freedom® collection, professional collection handles planning notes width: the minimum required cutout width is 35 1/2" (900 mm). depth: the minimum required cutout depth is 24" (610 mm). the refrigerator door panels will protrude [...] 1 800 735 4328 : 1 800 735 4328 . The final reviewed registry supersedes this earlier audit value. PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
T36BT120NS s1.img-b.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Cutout Size (HxWxD) (Inches) 84" Reviewed: 2026-09-05
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador T36BT120NS Product Specification assets.skulytics.io · Product Specification Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-05
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Minimum proud-install opening is 1/4 in wider than the appliance, giving 1/8 in per side. Calculation or inference: same-width 110/120 factory-panel chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory-panel chassis.
Measurement transferred: Left-side ventilation clearance. Relevant equivalence evidence: Minimum proud-install opening is 1/4 in wider than the appliance, giving 1/8 in per side.. Known differences: not separately recorded. Review decision: documented chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Minimum proud-install opening is 1/4 in wider than the appliance, giving 1/8 in per side. Calculation or inference: same-width 110/120 factory-panel chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory-panel chassis.
Measurement transferred: Right-side ventilation clearance. Relevant equivalence evidence: Minimum proud-install opening is 1/4 in wider than the appliance, giving 1/8 in per side.. Known differences: not separately recorded. Review decision: documented chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
84 in niche minus 83 9/16 in appliance height = 7/16 in. Calculation or inference: min_cutout_height_in - height_hinge_in.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: min_cutout_height_in - height_hinge_in.
Measurement transferred: Top clearance. Relevant equivalence evidence: 84 in niche minus 83 9/16 in appliance height = 7/16 in.. Known differences: not separately recorded. Review decision: documented cavity residual formula; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Manufacturer proud-install plan permits a 24 in cavity equal to the 24 in appliance depth. Calculation or inference: same-width 110/120 factory-panel chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory-panel chassis.
Measurement transferred: Rear clearance. Relevant equivalence evidence: Manufacturer proud-install plan permits a 24 in cavity equal to the 24 in appliance depth.. Known differences: not separately recorded. Review decision: documented chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Flush-install top-view diagram labels 7/8 in at the 90-degree full-access door position. Calculation or inference: same-width 110/120 factory-panel chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory-panel chassis.
Measurement transferred: Hinge-side wall clearance. Relevant equivalence evidence: Flush-install top-view diagram labels 7/8 in at the 90-degree full-access door position.. Known differences: not separately recorded. Review decision: documented chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Cabinet case width. Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
Conflict-free left/right or handle-style sibling propagation. Calculation or inference: same-width 110/120 factory chassis.
Why evidence from T36BT110NS applies
Target model: T36BT120NS. Supporting model: T36BT110NS. Manufacturer: Thermador. Product family and measurement relationship: same-width 110/120 factory chassis.
Measurement transferred: Adjoining-wall clearance (reviewed endpoint). Relevant equivalence evidence: Conflict-free left/right or handle-style sibling propagation.. Known differences: not separately recorded. Review decision: sibling chassis propagation; 2026-09-05.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
Selected: 35.5 in. Earlier retained values: 1 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
Model numbers covered: T36BT110NS. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
13 displayed measurements supported: Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Depth with doors open at 90°; Left-side ventilation clearance; Right-side ventilation clearance; Top clearance; Rear clearance; Hinge-side wall clearance; Cabinet case width; Adjoining-wall clearance (reviewed endpoint).
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-09-05. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.