This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-14. 4 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — thermador_t36bt120n_specification_sheetv2.pdf s1.img-b.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth without panel or handles 24 in.
Exact-model Thermador page visually verified: Overall depth without panel or handles 24 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth with factory panel 24 3/4 in.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth with factory panel and handles 27.75 in.
Exact-model Thermador page visually verified: Overall depth with factory panel and handles 27.75 in.
Other evidence found
24 in — superseded
files.bbystatic.com; location not retained. Model scope: not separately recorded. Raw value: l Height (Inches) 83 9/16 16" Min. - 85 1/2" Max. Overall Depth Without Panel or Handles (Inches) 24" Overall Depth With Panel (Inches) 24 3/4" Overall. The final reviewed registry supersedes this earlier audit value.
Document 101719930.pdf; page 2. Model scope: not separately recorded. Raw value: Conflict-free left/right or handle-style sibling propagation.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Exact-model Thermador page visually verified: Proud-install top view establishes 45 in overall depth at 90 degrees. Calculation or inference: 24-in case depth + printed 90-degree door projection.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador installation document — 101719903.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-04
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
Other evidence found
1 in — superseded
files.bbystatic.com; location not retained. Model scope: not separately recorded. Raw value: page 4 of 5 6 / 24 proud install top view clearance proud install cutout dimensions measurements in inches (mm) 351/2-36 (900-914) 1/8-3/8 (3-10) ≥ 24 (≥ 610) 33/4 (95) 105/8 (270) 115° 115° 21 (533) 90° 90° (a) c 84 (2134) ≤ 71/4 (≤ 185) (b) ≥ 4 (≥ 100) (c) ≥ 4 (≥ 100) (c) c2 d ≥ 4 (≥ 100) (c) c1 ≥ 24 (≥ 610) 351/2-36 (900-914) c1: c2: d: c: b: a: furniture return frameless cabinet framed cabinet filler area for water and electric line routing socket measurements in inches (mm) t36bt120ns 36-inch built-in french door refrigerator, 2 drawer, pre-assembled freedom® collection, professional collection handles planning notes width: the minimum required cutout width is 35 1/2" (900 mm). depth: the minimum required cutout depth is 24" (610 mm). the refrigerator door panels will protrude [...] 1 800 735 4328 : 1 800 735 4328 . The final reviewed registry supersedes this earlier audit value.
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — thermador_t36bt120n_specification_sheetv2.pdf s1.img-b.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Cutout Size (HxWxD) (Inches) 84" Reviewed: 2026-09-05
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-05
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Centered proud-install minimum opening leaves 1/8 in per side. Calculation or inference: (minimum cutout width - appliance width) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Centered proud-install minimum opening leaves 1/8 in per side. Calculation or inference: (minimum cutout width - appliance width) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: 84-in niche minus 83 9/16-in minimum appliance height. Calculation or inference: 84 - 83 9/16.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Proud-install cutout and appliance body are both 24 in deep. Calculation or inference: 24-in proud cutout - 24-in appliance depth.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization:
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-17
Migrated from hinge_side_wall_clearance_in (90 degrees (text also gives a fully open figure)). Exact-model Thermador page visually verified: Flush-install detail B labels 7/8 in for 90-degree full access.
Migrated from hinge_side_wall_clearance_in (90 degrees (text also gives a fully open figure)). Exact-model Thermador page visually verified: Flush-install detail B labels 7/8 in for 90-degree full access.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Thermador measurement source — 24f2a7082b546fc0cb8c4627ee4539801fffc429e241d7b174d7be01957a5fe9.pdf Publisher not recorded
Page 4
Value used by ExactFit
10.625 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 24f2a7082b546fc0cb8c4627ee4539801fffc429e241d7b174d7be01957a5fe9.pdf Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-10-14
10 5/8 in printed for proud installation, door at the printed maximum 115 degrees (larger of the printed per-door / standard-installation figures, owner rule). Read by the verification agent (run D24f2a7082b) from a document naming the model.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
10 5/8 in printed for proud installation, door at the printed maximum 115 degrees (larger of the printed per-door / standard-installation figures, owner rule). Read by the verification agent (run D24f2a7082b) from a document naming the model.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BT120NS-101719903.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall width 35.25 in.
Selected: 35.5 in. Earlier retained values: 1 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
PLANNING NOTES
Width: The minimum required cutout width is 35 1/2" (900 mm).
Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Electrical Supply: The electrical supply outlet (A) is recommended to be located in an adjacent cabinet for safety and serviceability. If it is not possible
due to the construction to connect the appliance to a power outlet next to it (A), connect the appliance to a power outlet behind the appliance (B).
This alternative position of the power outlet is permissible only if you can switch off the outlet with a circuit breaker in the fuse box.
Water Supply: A cold water supply is required for water dispenser and icemaker operation. Water pressure must be between 29 and 116 p.s.i.
The water supply is recommended to be located in an adjacent cabinet or other area that can be accessed after the appliance is installed.
Furniture Return: The metal frame hides unfinished case returns
assets.skulytics.io · Web source · secondary model/source
Model numbers covered: T36BT120NS. Publication/revision date: Not recorded. Reviewed: 2026-09-11.
12 displayed measurements supported: Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Depth with doors open at 90°; Left-side ventilation clearance; Right-side ventilation clearance; Top clearance; Rear clearance; Wall clearance for door open to 90°; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-14. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.