This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-14. 3 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 22707422_T36BB120SS_36-IN_BUILT-IN_BOTTOM_FREEZER_REFRIGERATOR-2_DRAWER-PROFESSIONAL_SERIES_HANDLES-Specifications.pdf askthermadorbestbuy.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
The same document as the value used above; location not retained. Model scope: not separately recorded. Raw value: page 4 of 5 5 / 24 proud install top view clearance proud install cutout dimensions measurements in inches (mm) 351/2-36 (900-914) 1/8-3/8 (3-10) ≥ 24 (≥ 610) 33/4 (95) 181/4 (463) 115° 3815/16 (989) 90° (a) c 84 (2134) ≤ 71/4 (≤ 185) (b) ≥ 4 (≥ 100) (c) ≥ 4 (≥ 100) (c) c2 d ≥ 4 (≥ 100) (c) c1 ≥ 24 (≥ 610) 351/2-36 (900-914) c1: c2: d: c: b: a: furniture return frameless cabinet framed cabinet filler area for water and electric line routing socket measurements in inches (mm) t36bb120ss 36-inch built-in bottom freezer refrigerator, 2 drawer, pre-assembled freedom® collection, professional collection handles planning notes width: the minimum required cutout width is 35 1/2" (900 mm). depth: the minimum required cutout depth is 24" (610 mm). the refrigerator door panels will protrude [...] method to cabinetry 4 fixation brackets, fixed at 4 corners of appliance, no visible screws front serviceable yes anti-tip bracket included yes frame kit included yes technical specs required power supp. The final reviewed registry supersedes this earlier audit value.
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth without panel or handles 24 in.
Exact-model Thermador page visually verified: Overall depth without panel or handles 24 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth with factory panel 24 3/4 in.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall depth with factory panel and handles 27.75 in.
askthermadorbestbuy.com; location not retained. Model scope: not separately recorded. Raw value: Height (Inches) 83 9/16 16" Min. - 85 1/2" Max." Overall Depth Without Panel or Handles (Inches) 24" Overall Depth With Panel (Inches) 24 3/4" Overall. The final reviewed registry supersedes this earlier audit value.
Document 101719915.pdf; page 2. Model scope: not separately recorded. Raw value: Conflict-free left/right or handle-style sibling propagation.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
62.9375 in · Fit role: Operating clearance. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 24 + 38 15/16 = 62 15/16 in
Confidence label: high.
Primary evidence
Thermador measurement source — 101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-10-14
The drawing measures the door at 90° from the cabinet (or case) front: 38 15/16" ; proud install: cabinet front at >= 24" (610 mm) from the back wall. Stored from the back, like every other model: 24 + 38 15/16 = 62 15/16 in (owner decision 2026-10-14). The printed 38 15/16" is the front-of-cabinet figure.
The drawing measures the door at 90° from the cabinet (or case) front: 38 15/16" ; proud install: cabinet front at >= 24" (610 mm) from the back wall. Stored from the back, like every other model: 24 + 38 15/16 = 62 15/16 in (owner decision 2026-10-14). The printed 38 15/16" is the front-of-cabinet figure. Calculation or inference: 24 + 38 15/16 = 62 15/16 in.
Other evidence found
37.9375 in — superseded
Document 101719915.pdf; page 2. Model scope: not separately recorded. Raw value: Conflict-free left/right or handle-style sibling propagation.. The final reviewed registry supersedes this earlier audit value.
38.9375 in — superseded
assets.skulytics.io; page 4. Model scope: not separately recorded. Raw value: Exact-model Thermador page visually verified: Proud-install top view establishes 38.9375 in overall depth at 90 degrees.. The final reviewed registry supersedes this earlier audit value.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-11
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Required cutout height 84 in.
Exact-model Thermador page visually verified: Required cutout height 84 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-09-05
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
PLANNING NOTES | Width: The minimum required cutout width is 35 1/2" (900 mm). | Depth: The minimum required cutout depth is 24" (610 mm). The refrigerator door panels will protrude slightly for a proud install.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Centered proud-install minimum opening leaves 1/8 in per side. Calculation or inference: (minimum cutout width - appliance width) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Centered proud-install minimum opening leaves 1/8 in per side. Calculation or inference: (minimum cutout width - appliance width) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: 84-in niche minus 83 9/16-in minimum appliance height. Calculation or inference: 84 - 83 9/16.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Exact-model Thermador page visually verified: Proud-install cutout and appliance body are both 24 in deep. Calculation or inference: 24-in proud cutout - 24-in appliance depth.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-10-14
Proud install top view: with the door at 90° it reaches 3 3/4" (95 mm) beyond the side of the appliance. The standard (proud) installation is stored (owner decision 2026-10-04 for built-ins).
Proud install top view: with the door at 90° it reaches 3 3/4" (95 mm) beyond the side of the appliance. The standard (proud) installation is stored (owner decision 2026-10-04 for built-ins).
Other evidence found
0.875 in — superseded
assets.skulytics.io; page 3. Model scope: not separately recorded. Raw value: Migrated from hinge_side_wall_clearance_in (90 degrees (text also gives a fully open figure)). Exact-model Thermador page visually verified: Flush-install detail B labels 7/8 in for 90-degree full access.. The final reviewed registry supersedes this earlier audit value.
Thermador measurement source — 101719896.pdf Publisher not recorded
Page 4
Value used by ExactFit
18.25 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — 101719896.pdf Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-10-14
18 1/4 in printed for proud installation. Read by the verification agent (run D008cc3d249) from a document naming the model.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
18 1/4 in printed for proud installation. Read by the verification agent (run D008cc3d249) from a document naming the model.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Thermador measurement source — T36BB120SS-101719896.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Thermador page visually verified: Overall width 35.25 in.
Selected: 27.75 in. Earlier retained values: 1 in, 24 in, 26.875 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Thermador page visually verified: Overall depth with factory panel and handles 27.75 in.
Selected: 62.9375 in. Earlier retained values: 37.9375 in, 38.9375 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
The drawing measures the door at 90° from the cabinet (or case) front: 38 15/16" ; proud install: cabinet front at >= 24" (610 mm) from the back wall. Stored from the back, like every other model: 24 + 38 15/16 = 62 15/16 in (owner decision 2026-10-14). The printed 38 15/16" is the front-of-cabinet figure. Calculation or inference: 24 + 38 15/16 = 62 15/16 in.
Selected: 3.75 in. Earlier retained values: 0.875 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Proud install top view: with the door at 90° it reaches 3 3/4" (95 mm) beyond the side of the appliance. The standard (proud) installation is stored (owner decision 2026-10-04 for built-ins).
Publisher not recorded · Retained document · Scope not established
Model numbers covered: Not explicitly retained. Publication/revision date: Not recorded. Reviewed: 2026-10-14.
4 displayed measurements supported: Depth with doors open at 90°; Minimum cutout depth; Wall clearance for door open to 90°; Wall clearance for fully open door.
Availability: retained review record; original URL unavailable in the record.
Evidence reflects the sources reviewed on 2026-10-14. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.