Measurement evidence for Samsung RF90F29BECR

This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.

Samsung RF90F29BECR

Unknown configuration · Unknown depth class
Market status: Active (recorded 2026-08-17)

View model fit check

Evidence summary

Complete mixed evidence

0exact-model manufacturer values
0verified equivalent/same-chassis values
15secondary-source-only values
1values with unresolved source details

Last reviewed: 2026-09-05. 2 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.

Counts use distinct measurement records. Left and right ventilation share one per-side source record.

Some measurements on this page are not supported by an exact-model document. Each affected row identifies the model relationship and supporting evidence.

Measurements and supporting evidence

MeasurementValue usedEvidence statusPrimary sourceLocationDetails
Overall width35.75 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Product width 35 3/4 in
Cabinet height68.875 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Dimensions without hinges and doors: height 68 7/8 in
Height with hinge / controlling height70.25 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Dimensions with hinges and doors: height 70 1/4 in
Depth without door29.375 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Dimensions without hinges and doors: depth 29 3/8 in
Depth with door, without handles34.25 in Secondary source only · Calculated/inferredRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: No projecting exterior handle; depth less handles equals closed overall depth 34.25 in
Depth with handle34.25 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Dimensions with hinges and doors: depth 34 1/4 in
Depth with doors open at 90°48.5 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: 90-degree top-view product depth 48 1/2 in
Minimum cutout width36.5 in Secondary source only · Calculated/inferredRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Reviewed product width and per-side installation clearance; width_doors_closed_in + 2 * side_clearan
Minimum cutout height70.625 in Secondary source only · Calculated/inferredRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Samsung installation envelope: 70.25 in appliance endpoint + 0.375 in clearance = 70.625 in.
Minimum cutout depth31.375 in Secondary source only · Calculated/inferredRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Minimum opening depth derived from case-only depth 29.375 in plus documented rear clearance 2.0 in.
Left-side ventilation clearanceUnknown? Not found · Calculated/inferredSamsung measurement source — local-cache manufacturer-family consensus
Publisher not recorded
Retained specification excerpt: Conflict-free 7-character model-series consensus (RF90F29) from 3 directly evidenced models; example
Top clearance0.375 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Exact-model cached Samsung clearance statement: top_clearance_in=0.375 in; 2 copy/copies, 1 domain(s
Rear clearance2 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: 2" minimum clearance at rear
Hinge-side wall clearance3.75 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Page 2
Cabinet case width35.75 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Dimensions without hinges and doors: width 35 3/4 in
Adjoining-wall clearance (reviewed endpoint)0.375 in Secondary source onlyRF90F29BECR
www.canadianappliance.ca
Retained specification excerpt: Allow 3/8 in minimum clearance at sides

Measurements not established

Left-side ventilation clearance

Not found for safe fit use. Sources retained: local-cache manufacturer-family consensus. No rejected related-model candidate is identified in the retained record.

A low-confidence, consensus, or unspecified-minimum assumption does not establish a safe fit requirement.

An unknown required input can make the fit result Uncertain. Confirm the current exact-model installation document before purchase.

Right-side ventilation clearance

Not found for safe fit use. Sources retained: local-cache manufacturer-family consensus. No rejected related-model candidate is identified in the retained record.

A low-confidence, consensus, or unspecified-minimum assumption does not establish a safe fit requirement.

An unknown required input can make the fit result Uncertain. Confirm the current exact-model installation document before purchase.

Source documents and pages

RF90F29BECR

www.canadianappliance.ca · Web source · secondary model/source

Model numbers covered: RF90F29BECR. Publication/revision date: Not recorded. Reviewed: 2026-09-04.

15 displayed measurements supported: Overall width; Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Depth with doors open at 90°; Minimum cutout width; Minimum cutout height; Minimum cutout depth; Top clearance; Rear clearance; Hinge-side wall clearance; Cabinet case width; Adjoining-wall clearance (reviewed endpoint).

Availability: retained review record; original URL retained (current availability not rechecked).

Open original source ↗

Samsung measurement source — local-cache manufacturer-family consensus

Publisher not recorded · Retained document · Scope not established

Model numbers covered: Not explicitly retained. Publication/revision date: Not recorded. Reviewed: 2026-09-05.

2 displayed measurements supported: Left-side ventilation clearance; Right-side ventilation clearance.

Availability: retained review record; original URL unavailable in the record.

Evidence reflects the sources reviewed on 2026-09-05. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.