This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-13. 2 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: width_doors_closed_in = 36 in.
Validated Monogram specification value: width_doors_closed_in = 36 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: height_case_in = 83.5 in.
Validated Monogram specification value: height_case_in = 83.5 in.
Other evidence found
84 in — superseded
Document 104290105.pdf (p.8); page 8. Model scope: not separately recorded. Raw value: Overall Height -> 84" (213.36 cm). The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: height_hinge_in = 84 in.
Validated Monogram specification value: height_hinge_in = 84 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: depth_case_only_in = 23.5 in.
Validated Monogram specification value: depth_case_only_in = 23.5 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: depth_less_handles_in = 25.75 in.
28.3125 in · Fit role: Traffic projection. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: published depth without handle + published 2 9/16-in custom-handle projection
Confidence label: high.
Primary evidence
Monogram measurement source — ZISB360DNII_104290106.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-11
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 28.3125 in.
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 28.3125 in. Calculation or inference: published depth without handle + published 2 9/16-in custom-handle projection.
Other evidence found
25.75 in — superseded
Document 104290106.pdf; page 3. Model scope: not separately recorded. Raw value: Overall Depth
25 3/4"(65.4 cm). The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Exact-model Monogram dimensional page visually prints the mapped depth_doors_open_90_in endpoint as 44.125 in. Calculation or inference: published case depth + published Door Clearance at 90 degrees.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: min_cutout_width_in = 35.5 in.
Validated Monogram specification value: min_cutout_width_in = 35.5 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — 104290106.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-05
Manufacturer specification gives nominal cutout height 84 in with +/- 1/2 in adjustment range.
Manufacturer specification gives nominal cutout height 84 in with +/- 1/2 in adjustment range.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — ZISB360DNII_104290106.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-11
Exact-model Monogram dimensional page visually prints the mapped min_cutout_depth_in endpoint as 24 in.
Exact-model Monogram dimensional page visually prints the mapped min_cutout_depth_in endpoint as 24 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Cutout is 1/2 in wider than the cabinet body, giving 1/4 in per side.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Cutout is 1/2 in wider than the cabinet body, giving 1/4 in per side.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Nominal 84 in cutout equals the 84 in highest appliance endpoint; adjustment range is handled by leveling.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
24 in cutout minus 23 1/2 in cabinet depth = 1/2 in behind the case.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization:
Confidence label: high.
Primary evidence
Monogram measurement source — ZISB360DNII_104290106.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-17
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact-model Monogram door-swing drawing visually prints the minimum adjacent-wall clearance as 4 9/16 in; corrected from a truncated decimal.
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact-model Monogram door-swing drawing visually prints the minimum adjacent-wall clearance as 4 9/16 in; corrected from a truncated decimal.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Monogram measurement source — 104290106.pdf Publisher not recorded
Page 3
Value used by ExactFit
15 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — 104290106.pdf Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-10-13
"Allow 13" (33.0) min clearance for 130° door swing" and "Allow 15" min clearance for 130° door swing" (one per door); the larger is stored (owner rule for clearances).
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
"Allow 13" (33.0) min clearance for 130° door swing" and "Allow 15" min clearance for 130° door swing" (one per door); the larger is stored (owner rule for clearances).
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104290106.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Validated Monogram specification value: case_width_in = 35 in.
Selected: 28.3125 in. Earlier retained values: 25.75 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 28.3125 in. Calculation or inference: published depth without handle + published 2 9/16-in custom-handle projection.
Evidence reflects the sources reviewed on 2026-10-13. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.