This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-15. 4 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: width_doors_closed_in = 35.75 in.
Validated Monogram specification value: width_doors_closed_in = 35.75 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: height_case_in = 83.6875 in.
Validated Monogram specification value: height_case_in = 83.6875 in.
Other evidence found
83.875 in — superseded
Document 104296181.pdf (p.1); page 1. Model scope: not separately recorded. Raw value: Overall Height -> 83 7/8" (213 cm). The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: height_hinge_in = 83.875 in.
Validated Monogram specification value: height_hinge_in = 83.875 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: depth_case_only_in = 22.125 in.
Validated Monogram specification value: depth_case_only_in = 22.125 in.
Other evidence found
22.875 in — superseded
An earlier brand-wide assumption (no document for this model); location not retained. Model scope: not separately recorded. Raw value: Monogram ZIC363IPVRH cached left/right-hinge chassis match. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: depth_less_handles_in = 24.75 in.
27.3125 in · Fit role: Traffic projection. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: published depth without handle + published Statement-handle projection
Confidence label: high.
Primary evidence
Monogram measurement source — ZIC363IPVLH_104296186.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 27.3125 in.
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 27.3125 in. Calculation or inference: published depth without handle + published Statement-handle projection.
Other evidence found
24.75 in — superseded
Document 104296186.pdf; page 2. Model scope: not separately recorded. Raw value: Overall Depth
24 3/4" (62.9 cm). The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Manufacturer side view gives total 90-degree/open depth 61 11/16 in; 39 9/16 in is the separate open-width dimension.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: min_cutout_width_in = 36 in.
Validated Monogram specification value: min_cutout_width_in = 36 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — 104296185.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-05
1. Cabinet cutout depth must be 25" | 2. Cabinet cutout height must be 84" | 3. Cabinet cutout interior surfaces should be fully finished to a minimum depth of 6"
1. Cabinet cutout depth must be 25" | 2. Cabinet cutout height must be 84" | 3. Cabinet cutout interior surfaces should be fully finished to a minimum depth of 6"
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — 104296184.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 20 Reviewed: 2026-09-05
Electrical and water supply must be located as shown. | The Cutout Depth Must Be 25". | 6" (15.2)
Electrical and water supply must be located as shown. | The Cutout Depth Must Be 25". | 6" (15.2)
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
36 in cutout minus 35 3/4 in appliance width, divided equally = 1/8 in per side.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
36 in cutout minus 35 3/4 in appliance width, divided equally = 1/8 in per side.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
84 in cutout minus 83 7/8 in highest appliance endpoint = 1/8 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
25 in cutout minus 24 3/4 in finished handleless appliance depth = 1/4 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization:
Confidence label: high.
Primary evidence
Monogram measurement source — ZIC363IPVLH_104296186.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-17
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact-model Monogram door-swing drawing visually prints the minimum adjacent-wall clearance as 4 9/16 in; corrected from a truncated decimal.
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact-model Monogram door-swing drawing visually prints the minimum adjacent-wall clearance as 4 9/16 in; corrected from a truncated decimal.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Monogram measurement source — 104296186.pdf Publisher not recorded
Page 4
Value used by ExactFit
21.5625 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram measurement source — 104296186.pdf Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Page 4 Reviewed: 2026-10-15
21.5625 in printed: D2db3efe5f2 p.4; left; condition: door fully open 115 degrees; based on handle projection of 2 9/16 inches and 2-inch hand clearance (larger of the printed figures, owner rule). Read by the verification agent from a document naming the model.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
21.5625 in printed: D2db3efe5f2 p.4; left; condition: door fully open 115 degrees; based on handle projection of 2 9/16 inches and 2-inch hand clearance (larger of the printed figures, owner rule). Read by the verification agent from a document naming the model.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Monogram installation document — 104296186.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Validated Monogram specification value: case_width_in = 35.75 in.
Selected: 27.3125 in. Earlier retained values: 24.75 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Monogram drawing visually verifies the no-handle depth and the applicable handle projection; exact calculation yields 27.3125 in. Calculation or inference: published depth without handle + published Statement-handle projection.
Model numbers covered: ZIC363IPVLH. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
13 displayed measurements supported: Overall width; Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with doors open at 90°; Minimum cutout width; Left-side ventilation clearance; Right-side ventilation clearance; Top clearance; Rear clearance; Wall clearance for fully open door; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-15. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.