This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-09-11. 4 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Standardized installed configuration. Calculation or inference: 21.5-in case + standard 3/4-in furniture panel.
Other evidence found
21.5 in — superseded
Document 74536124.pdf (p.3); page 3. Model scope: not separately recorded. Raw value: Appliance depth in in.(mm) -> 21 1/2 (546). The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele measurement source — 74536124.pdf assets.skulytics.io · Specification sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-05
Exact-model US Miele product sheet explicitly states min_cutout_height_in=69.875 in; supersedes prior metric-normalized/family value 69.75.
Exact-model US Miele product sheet explicitly states min_cutout_height_in=69.875 in; supersedes prior metric-normalized/family value 69.75.
Other evidence found
69.75 in — superseded
The same document as the value used above; page 2. Model scope: not separately recorded. Raw value: Exact-model Miele product sheet: minimum niche height 1772 mm; normalized to nearest 1/8 in = 69.75 in.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele measurement source — 74536124.pdf assets.skulytics.io · Specification sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-05
Exact-model US Miele product sheet explicitly states min_cutout_depth_in=21.75 in; supersedes prior metric-normalized/family value 21.625.
Exact-model US Miele product sheet explicitly states min_cutout_depth_in=21.75 in; supersedes prior metric-normalized/family value 21.625.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
0 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: (min_cutout_width_in - max(case_width_in,width_doors_closed_in)) / 2
Miele measurement source — KFN7795D-74536124.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0 in exactly. This is an installation reveal, normalized to the database side_ventilation_clearance_in term.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0 in exactly. This is an installation reveal, normalized to the database side_ventilation_clearance_in term. Calculation or inference: (min_cutout_width_in - max(case_width_in,width_doors_closed_in)) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
0 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: (min_cutout_width_in - max(case_width_in,width_doors_closed_in)) / 2
Miele measurement source — KFN7795D-74536124.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0 in exactly. This is an installation reveal, normalized to the database side_ventilation_clearance_in term.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0 in exactly. This is an installation reveal, normalized to the database side_ventilation_clearance_in term. Calculation or inference: (min_cutout_width_in - max(case_width_in,width_doors_closed_in)) / 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Miele measurement source — KFN7795D-74536124.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.125 in exactly. This is an installation reveal, normalized to the database top_clearance_in term.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.125 in exactly. This is an installation reveal, normalized to the database top_clearance_in term. Calculation or inference: min_cutout_height_in - max(height_case_in,height_hinge_in).
Other evidence found
0 in — superseded
Document 74536124.pdf; page 2. Model scope: not separately recorded. Raw value: Top cavity delta from exact-model sheet: normalized minimum niche height 69.75 in minus highest verified appliance height 69.75 in = 0 in.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Miele measurement source — KFN7795D-74536124.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-11
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.25 in exactly. This is an installation reveal, normalized to the database rear_clearance_in term.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.25 in exactly. This is an installation reveal, normalized to the database rear_clearance_in term. Calculation or inference: min_cutout_depth_in - depth_case_only_in.
Other evidence found
0.125 in — superseded
Document f89cf24c965b99d758d1d2a0286f52073c64bb62c5576df34865ec182a7f2ec7.pdf; page 24. Model scope: not separately recorded. Raw value: Rear cavity clearance derived from verified niche depth 21.625 in minus case-only depth 21.5 in = 0.125 in. Base evidence: niche depth of 21 5/8". The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Miele installation document — 74536124.pdf (p.3) assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 3 Reviewed: 2026-09-04
Selected: 0.125 in. Earlier retained values: 0 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.125 in exactly. This is an installation reveal, normalized to the database top_clearance_in term. Calculation or inference: min_cutout_height_in - max(height_case_in,height_hinge_in).
Selected: 0.25 in. Earlier retained values: 0.125 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Exact-model Miele technical-data page was visually checked. The printed niche and appliance dimensions are high-confidence operands; applying the Miele built-in cavity-residual rule reproduces 0.25 in exactly. This is an installation reveal, normalized to the database rear_clearance_in term. Calculation or inference: min_cutout_depth_in - depth_case_only_in.
Evidence reflects the sources reviewed on 2026-09-11. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.