This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-09-05. 3 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row identifies the model relationship and supporting evidence.
Measurements and supporting evidence
Measurement
Value used
Evidence status
Primary source
Location
Details
Overall width
35.8125 in
✓ Conflicting sources — resolved
Midea MRF29D9BST User Manual assets.skulytics.io
Page 7
Value used by ExactFit
35.8125 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
35.8 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Exact-model or explicitly covered Midea dimensional source.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST None assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Official profile drawing labels 68.7 in below the 69.9-in overall endpoint.
Official profile drawing labels 68.7 in below the 69.9-in overall endpoint.
Other evidence found
69.9 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Official profile drawing labels 68.7 in below the 69.9-in overall endpoint.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
69.9 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Exact-model or explicitly covered Midea dimensional source.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
36.1 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Exact-model or explicitly covered Midea dimensional source.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
36.1 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Exact-model or explicitly covered Midea dimensional source.
Effect on fit result
This is traffic projection. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Unknown · Fit role: Operating clearance. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: shared MRF29D6/D9 cabinet and door envelope
Confidence label: medium.
Primary evidence
MRF29D3AST_Costco_Spec Sheet_Final images.webfronts.com · Web source Model scope: Not established Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Propagated 90-degree depth from the matching MRF29D6 29-cu-ft chassis.
36.0625 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 35.8125 + 2 * 0.125
Confidence label: medium.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-04
Width plus documented >1/8-in installation clearance each side.
Width plus documented >1/8-in installation clearance each side. Calculation or inference: 35.8125 + 2 * 0.125.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Minimum opening height is the verified highest appliance endpoint plus the documented top clearance.
Minimum opening height is the verified highest appliance endpoint plus the documented top clearance. Calculation or inference: max(height_case_in,height_hinge_in) + top_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Minimum opening depth is the verified cabinet depth plus the documented rear clearance.
Minimum opening depth is the verified cabinet depth plus the documented rear clearance. Calculation or inference: depth_case_only_in + rear_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Exact-model manufacturer manual specifies 1 in top, 2 in rear, and 1/8 in side clearances.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: Migrated from side_clearance_wall_in by documented endpoint semantics
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Legacy reviewed field migration; endpoint indicators=['side wall']; Exact manual requires at least 2-3/8 in to a side wall.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
35.8 in — superseded
105608381.pdf; page 4. Model scope: not separately recorded. Raw value: W x D x H)
35.8 x 36.1 x 69.9in. The final reviewed registry supersedes this earlier audit value. Exact-model or explicitly covered Midea dimensional source.
Effect on fit result
This is informational only. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea MRF29D9BST User Manual assets.skulytics.io · User Manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-04
Exact manual requires at least 2-3/8 in to a side wall.
Evidence reflects the sources reviewed on 2026-09-05. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.