This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-31. 4 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Exact-model or explicitly covered Midea dimensional source.
Other evidence found
33.9 in — superseded
www.midea.com; location not retained. Model scope: not separately recorded. Raw value: ysical Specifications Product Width (in.) 35.8 in Product Depth (in.) 33.9 in Product Height (in.) 69.9 in Product Weight (lbs). The final reviewed registry supersedes this earlier audit value.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea measurement source — mehwptftnntm.pdf images.webfronts.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Cached exact-model specification states Depth with Door Open 90 degrees = 48.1 in.
43.8 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 35.8 + 2 * 4 = 43.8
Confidence label: high.
Primary evidence
Midea measurement source — Midea_MRF29D6AST_manual_2026-10-31.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-10-31
Midea MRF29D6AST manual p7: "Allow over 4" of clearance from each adjacent wall". Opening width = 35.8 + 4 + 4 = 43.8 in. The earlier figure used 10 cm (3.937 in) instead of the printed 4 in (Codex measurement review 2026-10-31).
Midea MRF29D6AST manual p7: "Allow over 4" of clearance from each adjacent wall". Opening width = 35.8 + 4 + 4 = 43.8 in. The earlier figure used 10 cm (3.937 in) instead of the printed 4 in (Codex measurement review 2026-10-31). Calculation or inference: 35.8 + 2 * 4 = 43.8.
Other evidence found
43.674 in — superseded
Document 77836210.pdf; page 7. Model scope: not separately recorded. Raw value: Width plus documented >4-in clearance on each side.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Minimum opening height is the verified highest appliance endpoint plus the documented top clearance. Calculation or inference: max(height_case_in,height_hinge_in) + top_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Minimum opening depth is the verified cabinet depth plus the documented rear clearance. Calculation or inference: depth_case_only_in + rear_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea measurement source — 77836210.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea measurement source — 77836210.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea measurement source — 77836210.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea measurement source — 77836210.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Exact-model manufacturer manual requires over 4 in from each adjacent wall.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization:
Confidence label: high.
Primary evidence
Midea measurement source — 77836210.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-17
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact manual requires over 4 in from each adjacent wall.
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (door angle not stated, 6 in or less). Exact manual requires over 4 in from each adjacent wall.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Midea installation document — 105608296.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Exact-model or explicitly covered Midea dimensional source.
Selected: 43.8 in. Earlier retained values: 43.674 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Midea MRF29D6AST manual p7: "Allow over 4" of clearance from each adjacent wall". Opening width = 35.8 + 4 + 4 = 43.8 in. The earlier figure used 10 cm (3.937 in) instead of the printed 4 in (Codex measurement review 2026-10-31). Calculation or inference: 35.8 + 2 * 4 = 43.8.
Model numbers covered: MRF29D6AST. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
7 displayed measurements supported: Overall width; Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-31. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.