Measurement evidence for Frigidaire Professional PRFC2383AF
This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-25. 3 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Measurements and supporting evidence
Measurement
Value used
Evidence status
Primary source
Location
Details
Overall width
36 in
✓ Verified — retained secondary source
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
36 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
68.3 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
70 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
23.6 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
28.5 in · Fit role: Traffic projection.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
30.8 in · Fit role: Traffic projection.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
43.5 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-09
Frigidaire Professional installation-envelope calculation: case_width_in=35.6, side_ventilation_clearance_in=0.375; result=36.35 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments
Frigidaire Professional installation-envelope calculation: case_width_in=35.6, side_ventilation_clearance_in=0.375; result=36.35 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments Calculation or inference: case_width_in + 2 * side_ventilation_clearance_in.
Other evidence found
36.75 in — superseded
Document 74532853.pdf + Document 103504943.pdf; location not retained. Model scope: not separately recorded. Raw value: Derived minimum opening width 36.75 in from product width 36.0 in and explicit 0.375 in clearance on each side.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-09
Frigidaire Professional installation-envelope calculation: height_hinge_in=70, top_clearance_in=0.375; result=70.375 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments
Frigidaire Professional installation-envelope calculation: height_hinge_in=70, top_clearance_in=0.375; result=70.375 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments Calculation or inference: height_hinge_in + top_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-09
Frigidaire Professional installation-envelope calculation: depth_case_only_in=23.6, rear_clearance_in=1; result=24.6 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments
Frigidaire Professional installation-envelope calculation: depth_case_only_in=23.6, rear_clearance_in=1; result=24.6 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments Calculation or inference: depth_case_only_in + rear_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io
Page 8
Value used by ExactFit
0.375 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-05
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io
Page 8
Value used by ExactFit
0.375 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-05
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io
Page 8
Value used by ExactFit
0.375 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional measurement source — 103504943.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-05
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
plumbing and electrical connections: | • Sides & Top 3/8 inch (9.5 mm) | • Back 1 inch (25.4 mm) | deterministic pattern: installation_sides
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional installation document — 103504943.pdf assets.skulytics.io
Page 8
Value used by ExactFit
1 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 103504943.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 8 Reviewed: 2026-09-09
ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments
ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire Professional measurement source — PRFC2383A_EN-pdf.pdf frigidaire.bynder.com
Page 2
Value used by ExactFit
3.95 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: (43.5 - 35.6) / 2
Confidence label: high.
Primary evidence
Frigidaire Professional measurement source — PRFC2383A_EN-pdf.pdf frigidaire.bynder.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-10-25
Manufacturer page/document for Available Products: PRFC2383AF: Width of Cabinet 35 6/10"; Width With Doors 90° Open 43 1/2". Found 2026-10-25.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io
Page 1
Value used by ExactFit
35.6 in · Fit role: Informational only.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire Professional installation document — 74532853.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Selected: 36.35 in. Earlier retained values: 36.75 in. Endpoint definitions may differ; see the retained transcriptions and final review note.
Frigidaire Professional installation-envelope calculation: case_width_in=35.6, side_ventilation_clearance_in=0.375; result=36.35 in. Product source: 74532853.pdf. Clearance source: ity for models equipped with an automatic ice maker. Top Hinge Cover Front Screw Top Hinge Cover Rear Screw Lower Hinge Screw Top Hinge Screw Components Provided: Tools Necessary: Phillips Head or Quadrex Head Screwdriver (OR) OR ⅜" and ¼" Socket Wrench Adjustable Wrench OR ⅜" Fixed Wrench AND AND 6mm Allen Wrench INSTALLATION WARNING Installation Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: • Sides & Top ³⁄8 inch (9.5 mm) • Back 1 inch (25.4 mm) WARNING This appliance is intended for use in residential household and similar interior applications such as: • Kitchen / Kitchenette • Pantry Room • Basement • Enclosed Garage • Other interior residential-type environments Calculation or inference: case_width_in + 2 * side_ventilation_clearance_in.
Model numbers covered: PRFC2383AF. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
8 displayed measurements supported: Overall width; Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Depth with doors open at 90°; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-25. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.