This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-10-25. 3 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Retained specification excerpt: Exact-chassis specification: Height to Top of Refrigerator Case 64.9 in; finish variants share the s
Value used by ExactFit
64.9 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire measurement source — FRTE1622AS www.homedepot.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Exact-chassis specification: Height to Top of Refrigerator Case 64.9 in; finish variants share the s Reviewed: 2026-09-04
Exact-chassis specification: Height to Top of Refrigerator Case 64.9 in; finish variants share the same manufacturer dimensions.
Exact-chassis specification: Height to Top of Refrigerator Case 64.9 in; finish variants share the same manufacturer dimensions.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Frigidaire family installation-envelope calculation: case_width_in=27.5625, side_ventilation_clearance_in=3.93; result=35.4225 in. Product operand source: 83575470.pdf. Calculation or inference: case_width_in + 2 * side_ventilation_clearance_in.
Other evidence found
28.3125 in — superseded
An earlier brand-wide assumption (no document for this model); location not retained. Model scope: not separately recorded. Raw value: Derived minimum opening width 28.3125 in from product width 27.5625 in and explicit 0.375 in clearance on each side.. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire family installation-envelope calculation: height_hinge_in=64.9, top_clearance_in=3.93; result=68.83 in. Product operand source: 83575470.pdf. Calculation or inference: height_hinge_in + top_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire family installation-envelope calculation: depth_case_only_in=25.5938, rear_clearance_in=2.95; result=28.5438 in. Product operand source: 83575470.pdf. Calculation or inference: depth_case_only_in + rear_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 103506176.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 103506176.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 103506176.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-09
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 103506176.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 7 Reviewed: 2026-09-09
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides, Top 3.93" (100 mm) Back 2.95" (75 mm) To level the cabinet using the front leveling feet: • Lower the leveling feet on each side clockwise until they contact the fl oor. Lower Raise • Use the leveling feet (located on the front) ensuring all 4 corners of the unit are resting fi rmly on a solid fl oor. Turn the leveling feet clockwise to retract the feet and counterclockwi
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire measurement source — 83575470.pdf Publisher not recorded
Page 1
Value used by ExactFit
0.390625 in · Fit role: Operating clearance. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 27.953125 - 27.5625
Confidence label: high.
Primary evidence
Frigidaire measurement source — 83575470.pdf Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-10-25
Exact-model Frigidaire specification: Width With Doors 90° Open 27 61/64", Width of Cabinet 27 9/16". One door; the extra width is all on the hinge side: 25/64" beside a wall for the door to open to 90°.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
Exact-model Frigidaire specification: Width With Doors 90° Open 27 61/64", Width of Cabinet 27 9/16". One door; the extra width is all on the hinge side: 25/64" beside a wall for the door to open to 90°. Calculation or inference: 27.953125 - 27.5625.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire installation document — 83575470.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Model numbers covered: FRTE1622AS. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
8 displayed measurements supported: Overall width; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Depth with doors open at 90°; Wall clearance for door open to 90°; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-10-25. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.