This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-09-05. 5 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row identifies the model relationship and supporting evidence.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Retained specification excerpt: Exact-model specification: Height to Top of Case 69.7 in.
Value used by ExactFit
69.7 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire measurement source — https://www.lowes.com/pd/Frigidaire-21-4-cu-ft-Counter-depth-Side-by-Side-Refrigerator-Stainless-Look/5015635209 www.lowes.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Exact-model specification: Height to Top of Case 69.7 in. Reviewed: 2026-09-04
Exact-model specification: Height to Top of Case 69.7 in.
Exact-model specification: Height to Top of Case 69.7 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
FRSG2115AV Side-by-Side Refrigerators | Ohio | Grove Alliance groveappliance.com
Retained specification excerpt: Plain exact-model specification row: Depth = 28.6875 in | Ohio | Grove Alliance Product Details. ENE
Value used by ExactFit
28.6875 in · Fit role: Traffic projection.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: medium.
Primary evidence
FRSG2115AV Side-by-Side Refrigerators | Ohio | Grove Alliance groveappliance.com · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Plain exact-model specification row: Depth = 28.6875 in | Ohio | Grove Alliance Product Details. ENE Reviewed: 2026-09-04
Plain exact-model specification row: Depth = 28.6875 in | Ohio | Grove Alliance Product Details. ENERGY STAR Certified, No. Height, 69 7/10". Width, 35 13/16". Depth, 28 11/16". Depth With Door 90° Open, 41 11/16". Total Capacity, 21.4 Cu.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Retained specification excerpt: Derived minimum opening width 36.3125 in from product width 35.8125 in and explicit 0.25 in clearanc
Value used by ExactFit
36.3125 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: max(case width, width doors closed) + 2 * explicit side clearance = 35.8125 + 2 * 0.25
Confidence label: medium.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Retained specification excerpt: Derived minimum opening width 36.3125 in from product width 35.8125 in and explicit 0.25 in clearanc Reviewed: 2026-09-04
Derived minimum opening width 36.3125 in from product width 35.8125 in and explicit 0.25 in clearance on each side.
Derived minimum opening width 36.3125 in from product width 35.8125 in and explicit 0.25 in clearance on each side. Calculation or inference: max(case width, width doors closed) + 2 * explicit side clearance = 35.8125 + 2 * 0.25.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire opening envelope: max(69.7, 69.7) + 1.0 = 70.7 in. Calculation or inference: max(height_case_in,height_hinge_in) + top_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Frigidaire opening envelope: 24.8125 + 2.0 = 26.8125 in. Calculation or inference: depth_case_only_in + rear_clearance_in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Unknown · Fit role: Operating clearance. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: hinge-side baseline = documented side ventilation clearance
Confidence label: medium.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Not established Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-05
Allow the following clearances for ease of installation, proper air circulation, and plumbing and electrical connections: Sides & Top 1" Back 2" Location • Choose a place that is near a ground ed electrical outlet. Do Not use an extension cord or an adapter plug. • If possible, place the unit out of direct sunlight and away from the range, dishwasher or other heat sources. • Install the appliance on a floor that is level and strong enough to support a fully loaded unit. CAUTION Do Not install t Hinge-side wall note is conditional and gives no separate numeric minimum; this value is the documented side-clearance baseline.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Frigidaire FRSG2115AV Product Specifications Sheet assets.skulytics.io · Product Specifications Sheet Model scope: Secondary source Publication/revision date: Not recorded Location: Page 1 Reviewed: 2026-09-04
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: medium.
Primary evidence
Frigidaire FRSG2115AV Complete Owner's Guide assets.skulytics.io · Complete Owner's Guide Model scope: Secondary source Publication/revision date: Not recorded Location: Page 6 Reviewed: 2026-09-04
• | Tilt the sides 1/4" (6 mm) from front to | back (to ensure the doors close and | deterministic pattern: installation_sides
Model numbers covered: FRSG2115AV. Publication/revision date: Not recorded. Reviewed: 2026-09-04.
6 displayed measurements supported: Overall width; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with doors open at 90°; Cabinet case width.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-09-05. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.