This page shows the sources and review decisions behind the measurements used by ExactFit. Evidence for the exact model is identified separately from verified equivalent-model or same-chassis evidence. Missing values remain Unknown.
Last reviewed: 2026-09-17. 6 retained source records. 0 unresolved conflicts. All inputs required by the cavity calculation are supported; an applicable cutout may replace additive requirements.
Counts use distinct measurement records. Left and right ventilation share one per-side source record.
Some measurements on this page are not supported by an exact-model document. Each affected row says where its value comes from.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165793.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Dimension H: Width 35 3/4 in. Dimension G (43 3/8 in.) is depth with fresh-food door open 90 degrees.
Dimension H: Width 35 3/4 in. Dimension G (43 3/8 in.) is depth with fresh-food door open 90 degrees.
Other evidence found
43.375 in — superseded
Document 105165879.pdf; page 2. Model scope: not separately recorded. Raw value: Width (in.) H -> 43-3/8. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165879.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165879.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165879.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165879.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe installation document — 105165879.pdf assets.skulytics.io · Installation manual Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-04
Retained specification excerpt: Depth Without Door 24.375 in Depth with Door Open 90°: 43.38 in | ® 22.1 Cu. Ft. Smart Counter-Depth
Value used by ExactFit
43.38 in · Fit role: Operating clearance.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — CAFE-ENERGY-STAR-22-1-Cu-Ft-Smart-Counter-Depth-French-Door-Refrigerator-with-Hot-Water-Dispenser-CYE22TP4MW2 Cafe · Web source Model scope: Exact model Publication/revision date: Not recorded Location: Retained specification excerpt: Depth Without Door 24.375 in Depth with Door Open 90°: 43.38 in | ® 22.1 Cu. Ft. Smart Counter-Depth Reviewed: 2026-09-04
Depth Without Door 24.375 in Depth with Door Open 90°: 43.38 in | ® 22.1 Cu. Ft. Smart Counter-Depth French ... CYE22TP4MW2. Width 35.750 in Case Depth Without Door 24.375 in Depth with Door Open 90° 43.375 in Depth Without Handle 30.25. Weight 365 lb Overall Depth 31.25
Depth Without Door 24.375 in Depth with Door Open 90°: 43.38 in | ® 22.1 Cu. Ft. Smart Counter-Depth French ... CYE22TP4MW2. Width 35.750 in Case Depth Without Door 24.375 in Depth with Door Open 90° 43.375 in Depth Without Handle 30.25. Weight 365 lb Overall Depth 31.25
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165880.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 34 Reviewed: 2026-09-10
Manufacturer installation instructions directly state that cabinet opening width W should not be less than 36 in.
Manufacturer installation instructions directly state that cabinet opening width W should not be less than 36 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
71.5 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: max(69, 70.5) + 1
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165880.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 27 Reviewed: 2026-09-10
Highest exact appliance-height endpoint from the exact-model Quick Specs plus the directly printed 1 in top clearance from the shared manufacturer installation instructions.
Highest exact appliance-height endpoint from the exact-model Quick Specs plus the directly printed 1 in top clearance from the shared manufacturer installation instructions. Calculation or inference: max(69, 70.5) + 1.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
26.375 in · Fit role: Cavity fit. Calculated or inferred value — not a directly printed measurement.
Original published value and unit: see retained transcription below. Normalization: 24.375 + 2
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165880.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 27 Reviewed: 2026-09-10
Exact case depth without door from the exact-model Quick Specs plus the directly printed 2 in back clearance from the shared manufacturer installation instructions.
Exact case depth without door from the exact-model Quick Specs plus the directly printed 2 in back clearance from the shared manufacturer installation instructions. Calculation or inference: 24.375 + 2.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Retained specification excerpt: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to
Value used by ExactFit
0.125 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — Cafe exact-family installation manuals cached in Tavily advanced results www.ajmadison.com · Web source Model scope: Equivalent model Publication/revision date: Not recorded Location: Retained specification excerpt: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to Reviewed: 2026-09-05
Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.
Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.
Why evidence from CYE22TP2MS1 applies
Target model: CYE22TP4MW2. Supporting model: CYE22TP2MS1. Manufacturer: Cafe. Product family and measurement relationship: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance..
Measurement transferred: Left-side ventilation clearance. Relevant equivalence evidence: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.. Known differences: not separately recorded. Reviewed 2026-09-17.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Retained specification excerpt: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to
Value used by ExactFit
0.125 in · Fit role: Cavity fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — Cafe exact-family installation manuals cached in Tavily advanced results www.ajmadison.com · Web source Model scope: Equivalent model Publication/revision date: Not recorded Location: Retained specification excerpt: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to Reviewed: 2026-09-05
Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.
Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.
Why evidence from CYE22TP2MS1 applies
Target model: CYE22TP4MW2. Supporting model: CYE22TP2MS1. Manufacturer: Cafe. Product family and measurement relationship: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance..
Measurement transferred: Right-side ventilation clearance. Relevant equivalence evidence: Corrected prior value 13.125 in (Min distance between side of case and wall, in
either direction, to allow doors to open fully (in.) K -> 13-1/8). Exact-family installation instructions: opening W must not be less than 36 in; 1/8 in side air clearance. Replaces door-swing wall clearance.. Known differences: not separately recorded. Reviewed 2026-09-17.
This is not exact-model documentation. ExactFit applies it only to the measurement above because the retained evidence supports the stated equivalence.
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the width comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165880.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 27 Reviewed: 2026-09-10
Manufacturer installation instructions CLEARANCES box directly prints Top = 1 in at the cabinet/hinge cover.
Manufacturer installation instructions CLEARANCES box directly prints Top = 1 in at the cabinet/hinge cover.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the height comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165880.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 27 Reviewed: 2026-09-10
Manufacturer installation instructions CLEARANCES box directly prints Back = 2 in.
Manufacturer installation instructions CLEARANCES box directly prints Back = 2 in.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This measurement supports the depth comparison. An applicable cutout can replace additive clearances. If a required input is unknown and no applicable alternative requirement is established, the result is Uncertain unless another known requirement proves Does not fit.
Source not recorded Publisher not recorded · Retained document Model scope: Not established Publication/revision date: Not recorded Location: Exact location not retained Reviewed: Not recorded
No retained excerpt is available.
The original source link has not yet been recovered from the retained records. This is a link-recovery gap, not a missing measurement. The final registry-verified value and audit text remain available above.
Why this value was used
No evidence decision recorded.
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization:
Confidence label: high.
Primary evidence
Cafe measurement source — 105165879.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-17
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (fully open). Exact-model Cafe dimension table: minimum distance between side of case and wall, in either direction, to allow doors to open fully = 13 1/8".
Migrated from hinge_side_wall_clearance_in+side_clearance_wall_in (fully open). Exact-model Cafe dimension table: minimum distance between side of case and wall, in either direction, to allow doors to open fully = 13 1/8".
Other evidence found
No materially different value is retained in the linked per-measurement audit records. This does not imply that every published source was searched.
Effect on fit result
This is operating clearance. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
Original published value and unit: see retained transcription below. Normalization: No separate conversion rule recorded; the stored normalized value is retained without additional rounding.
Confidence label: high.
Primary evidence
Cafe measurement source — CYE22TP4MW2-105165879.pdf assets.skulytics.io · Web source Model scope: Secondary source Publication/revision date: Not recorded Location: Page 2 Reviewed: 2026-09-10
Exact-model dimension drawing labels H as Width = 35 3/4 in; the H arrow visibly spans the refrigerator case body rather than the open doors.
Exact-model dimension drawing labels H as Width = 35 3/4 in; the H arrow visibly spans the refrigerator case body rather than the open doors.
Other evidence found
43.375 in — superseded
Document 105165879.pdf; page 2. Model scope: not separately recorded. Raw value: Width (in.) H -> 43-3/8. The final reviewed registry supersedes this earlier audit value.
Effect on fit result
This is informational only. It is shown for a separate on-site check and does not establish cavity fit or delivery access.
assets.skulytics.io · Web source · secondary model/source
Model numbers covered: CYE22TP4MW2. Publication/revision date: Not recorded. Reviewed: 2026-09-17.
6 displayed measurements supported: Cabinet height; Height with hinge / controlling height; Depth without door; Depth with door, without handles; Depth with handle; Wall clearance for fully open door.
Availability: retained review record; original URL retained (current availability not rechecked).
Evidence reflects the sources reviewed on 2026-09-17. Manufacturer specifications can change. Confirm the current exact-model installation document and site-specific conditions before purchase or installation.